The role of micro-CT in orthodontic bracket removal procedures

Dental burs are generally applied to rid teeth of residual adhesive after the removal of orthodontic brackets. During the process, these burs sustain wear degradation. The question arises, should these burs be single-use only or can they be used on another patient?

Employing micro-CT for nondestructive 3D imaging of used burs helps address this question. Cylinder With Endcut

The role of micro-CT in orthodontic bracket removal procedures

As numerous teenagers and parents know, current orthodontic treatment involves aligning and moving teeth by utilizing adhesively attached orthodontic appliances (Fig. 1A). To bond orthodontic brackets to the outer labial tooth surfaces, dental composites and resins are typically used (Fig. 1B).

Upon completion of the treatment, perhaps months or years later, the brackets and the dental materials must be removed (Fig. 1C).

Figure 1. To align teeth (A) orthodontists use brackets (B) and wires that apply forces to change tooth position and angle. Treatment ends (C) with bracket removal, when the teeth and dental arches have reached aesthetic, harmonious well-matching relations leading to functional occlusion and pleasing smile. Image Credit: Bruker BioSpin - NMR, EPR and Imaging

Removal of the adhesive residue is a crucial part of treatment and a clinical challenge for the treating orthodontist; the adhesive must be completely removed from the ­­tooth without resulting in any damage to the teeth.

High-velocity water-cooled burs are frequently used, which require precision, patience and complete patient cooperation. A range of grinding tools are available for this task, for instance, tungsten carbide burs (Fig. 2A, B).

Figure 2. These example burs are designed to gently remove polymer and composite adhering to the outer tooth surface. Although informative, the optical images (A) provide only partial information about the 3D design of the tool with little information on how it operates. Tomographic imaging (B) helps to better understand its mode of action. Image Credit: Bruker BioSpin - NMR, EPR and Imaging

However, there are questions surrounding the optimal use of these tools and how best to use them.

Figure 3 illustrates the steps typically involved in post-orthodontic adhesive removal, utilizing the flame-shaped H48L tungsten carbide bur (Komet Dental, Gebr. Brasseler GmbH & Ko. KG, Lemgo, Germany).

Figure 3. These example burs are designed to gently remove polymer and composite adhering to the outer tooth surface. Although informative, the optical images (A) provide only partial information about the 3D design of the tool with little information on how it operates. Tomographic imaging (B) helps to better understand its mode of action. Image Credit: Bruker BioSpin - NMR, EPR and Imaging

The tapered flutes (Fig. 2) of the bur have an angle of 52° in the direction of rotation and a modest quasi-orthogonal angle of 20° in relation to the shaft axis. This limits any potential damage to the surface of the teeth if/when the bur encounters enamel.

This particular bur has 12 flutes and a diameter of 0.14 mm and comes with various shafts developed to fit all available handpieces on the market.

Typical clinical use of the bur includes:

To closely evaluate the wear of the bur, micro-CT was utilized to record the 3D shape and details of the geometry of flute edges, with the high-resolution settings of a desktop instrument.

Figure 4. Economic considerations in choosing bur use, characteristics and contribution to clinical workflow. Image Credit: Bruker BioSpin - NMR, EPR and Imaging

The bur was imaged using the Bruker SkyScan 1275 micro-CT (Bruker micro-CT, Kontich, Belgium) fixed to a thin sample holder enabling close positioning to the X-ray source.

The high density of elements in the bur required employing the higher energy source settings of 100 kV (yielding µA) and a CU filter helped eliminate lower energies reducing substantial edge artefacts.

Optimal scans were acquired using 360° rotations, 6 µm effective pixel size. To reconstruct the image volumes, the NRecon (V. 1.7.4.2, Bruker micro-CT, Kontich, Belgium) was used.

When using the CTvox (V3.0, Bruker micro-CT, Kontich, Belgium), 3D images may be produced instantly, the reconstructed data in slices is immediately available as TIF or PNG files to be evaluated in any other package.

Examples of conventional cross-sectional slices can be acquired using the open-source ImageJ packages (https://imagej.net, V 1.52n) and its derivative, Fiji.

Stacks of images mean it is relatively straightforward to select, compare and measure alterations in shape at the same height in the sample both before and after use. Thus, it is possible to review bur abrasion associated with usage.

Direct comparison of the bur scans before and after the bracket removal session highlights selective zones with fine but significant regions of wear (Fig. 5).

Figure 5. Dental carbide wear in 2D sections along the bur axis (H48L tungsten carbide, Komet Dental, Gebr. Brasseler GmbH & Co. KG, Lemgo, Germany): Whereas obvious rounding of the edges is seen near the shaft (compare A with D, read/green arrows) extensive wear is observed in the central area(compare B and E, red/green arrows), with notable but less significant effects at regions ¾ up towards the tip (compare C with F, red/green arrows). Image Credit: Bruker BioSpin - NMR, EPR and Imaging

Rounding of flute edges is considered symmetric around the axis of the bur but diversified and non-uniform at various cross-sections across the length of the bur.

Although there are known properties (strength, wear resistance) relative to the materials used for bracket adhesion, the association between wear patterns during composite removal and the practitioner’s technique remains largely unknown.

Future studies will make it possible to quantify such measurements to show dimensions and locations in space that can act as key input for numerical modeling.

The nature of the reconstructions makes it well-suited for more comprehensive 3D analysis. By converting the data into binary (black and white) slices and into industry-standard STL files (export function of the inbuilt Fiji volume viewer), a thorough and detailed analysis of wear is made possible.

By using programs that have the capacity to align and compare the 3D data, there is the potential to visualize and quantify the area of wear and carbide substance loss. For example, the 3D analysis software Geomagic Control (3D Systems Inc., Rock Hill, S.C., U.S.A.) highlights the variations in the 3D deviation (mismatch, in 3D) between the original unused and worn bur (Fig. 6).

Figure 6. Superimposition and comparison of the bur volumes before and after use reveal important regionally varying differences in the amount of remaining substance (Tungsten carbide in this case). The green traces indicate a mismatch (averaging at about 130 μm in the flutes) with a clear trend for loss, as opposed to yielding or deformation of the flutes. Image Credit: Bruker BioSpin - NMR, EPR and Imaging

It can be observed that significant wear is seen in the central region of the flutes and at the bur tip. The inclination is that these are related to the adhesive properties, the geometry and hardness of the bur, as well as the clinical technique being used.

Superimposition of the virtual data acquired before and after bur use highlighted that wear appears in the central region up to two-thirds of the height of the bur. Wear never surpassed 1 mm in any direction (Fig. 6).

The flutes are significantly worn after usage and would therefore necessitate greater force and an extended treatment time to eradicate any remaining composite on the surface of the teeth, possibly leading to dangerous tooth overheating.

The evaluations from the 3D micro-CT imaging imply the recommendation that a bur should be limited to just one debonding session in a single patient. However, further comparisons with different usage protocols and bonding materials are required to investigate how general this single-use recommendation should be.

Bruker BioSpin offers the world's most comprehensive range of NMR and EPR spectroscopy and preclinical research tools. Bruker BioSpin develops, manufactures and supplies technology to research establishments, commercial enterprises and multi-national corporations across countless industries and fields of expertise.

Sponsored Content Policy: News-Medical.net publishes articles and related content that may be derived from sources where we have existing commercial relationships, provided such content adds value to the core editorial ethos of News-Medical.Net which is to educate and inform site visitors interested in medical research, science, medical devices and treatments.

Last updated: Mar 11, 2022 at 1:04 AM

Please use one of the following formats to cite this article in your essay, paper or report:

Bruker BioSpin - NMR, EPR and Imaging. (2022, March 11). The role of micro-CT in orthodontic bracket removal procedures. News-Medical. Retrieved on January 15, 2024 from https://www.news-medical.net/whitepaper/20210628/The-role-of-micro-CT-in-orthodontic-bracket-removal-procedures.aspx.

Bruker BioSpin - NMR, EPR and Imaging. "The role of micro-CT in orthodontic bracket removal procedures". News-Medical. 15 January 2024. <https://www.news-medical.net/whitepaper/20210628/The-role-of-micro-CT-in-orthodontic-bracket-removal-procedures.aspx>.

Bruker BioSpin - NMR, EPR and Imaging. "The role of micro-CT in orthodontic bracket removal procedures". News-Medical. https://www.news-medical.net/whitepaper/20210628/The-role-of-micro-CT-in-orthodontic-bracket-removal-procedures.aspx. (accessed January 15, 2024).

Bruker BioSpin - NMR, EPR and Imaging. 2022. The role of micro-CT in orthodontic bracket removal procedures. News-Medical, viewed 15 January 2024, https://www.news-medical.net/whitepaper/20210628/The-role-of-micro-CT-in-orthodontic-bracket-removal-procedures.aspx.

15N TROSY NMR for a Fresh View on Protein Macro-Molecules

Accurate Assessment of Solid Fat Content Using minispec Benchtop TD-NMR System

Advances in 2D NMR Spectroscopy of Monoclonal Antibodies

Advantages and Applications of Bruker’s MRI CryoProbe Series

An Innovative Approach to Quantitating CBD

An Overview of Proton Detection in Biological Samples Under Ultra-Fast Magic Angle Spinning

Analytical Techniques for the Characterisation of Diesel

Application of Cryogenically Cooled Resonators for High-Resolution Brain Imaging and Functional Cardiac Imaging

Application of Magnetic Resonance Spectroscopic Imaging (MRSI) to Produce Molecular Images of Mouse Brain Tumors

Biofluids Sample Quality in Metabolomic Research

Body Composition Analysis (BCA) Using minispec Analyzer

BOLD MRI as a New Method for Monitoring Hypoxia in Tumors

Bromine-Containing, Marine-Derived Products as Serotonin Modulators and Potential Antidepressants

Cardiac MR Imaging to Assess Heart Disease in Mice

Characterizing Intrinsically Disordered Proteins with NMR

Combating Anti-Malarial Resistance: The Preclinical Way

Combining Electron Paramagnetic Resonance and Atomic Force Microscopy to Elucidate Oxidative Stress in Eye Disorders

Comparing Root Canal Removal Techniques with Micro-CT

Correlations Between Microbiota and Hyperglycemia in Gestational Diabetes

Could Fragment-Based Screening Using NMR Tackle Antibiotic Resistance?

Dedicated minispec TD-NMR Analyzers for Industrial Quality Control Applications

Detailed Considerations for Outfitting Preclinical In Vivo Imaging Laboratory

Determination of Fat and Moisture Using TD-NMR Snack Food Analyzers

Determination of Hydrogen Content in Hydrocarbons Using minispec NMR Method

Electron Paramagnetic Resonance Aids Cancer Drug Development

Electron Spin Resonance Spectroscopy Allows Quick Authentication of Cooking Oil

Ensuring the Quality of Manufactured Heparin

EPR Analysis of Mobile Phone Glass Following Exposure to Ionizing Radiation

EPR Application Spotlight: Analyzing the Shelf Life of Polysorbates for the Pharmaceutical Industry

EPR Spectroscopy is Expanding our Knowledge of Parkinson's Disease

Evaluating Fish and Cardiovascular Health Using 1H-NMR

Exploring Applications of Time Domain Nuclear Magnetic Resonance

Exploring the Role of GDF15 in Nutrition

Exploring the Structure of Elastomeric Ionomers

First In Vivo Study Explores Insights Gained from MRI of Brain Cell Water

fMRI Used to Identify Neuronal Networks Activated by VTA or Hippocampal CA3 Stimulation

Functional Connectivity Magnetic Resonance Imaging of the Rat Brain

Genetically Engineering Rat Gliomas to Enable Clinically Relevant Imaging of Human Glioblastoma

High Resolution BOLD Functional MRI Provides New Insights on Rat Brain

How Can NMR Help To Identify Novel Cervical Cancer Treatments?

How Mass Spec and PET/CT Unlocked a New Target for Gastric Cancer Treatments

How NMR Revealed p53's Hidden Abilities

How to Detect Acute Kidney Injuries

How to Detect Fraudulent Additives in Milk Powders

How to Detect Synthetic Cannabinoids in Hair

How to Develop New Healthier Fats

How to Differentiate Bordeaux Red Wines to Prevent Wine Fraud

How to Distinguish Organic Coffee with NMR-Based Metabolmics

How to Ensure Consistent Quantification with Preclinical MRI

Identifying American Lagers with NMR Spectroscopy

Identifying Biomarkers for Guillain–Barré Syndrome

Identifying New Agents for Lowering Blood Glucose Levels

Immune Programming in Plants Identified by EPR

Immuno-PET Imaging Offers Less Invasive Diagnostic and Monitoring Approach for IBD

Insights on Correlates of Success in HIV Vaccination

Integrated Analyses Tackle the Rise Of “Legal Highs”

Investigating a Neuroprotective Pentapeptide in a Murine Model of Intracerebral Hemorrhage

Investigating Cardiovascular Risk in Patients with Type 1 Diabetes

Investigating the Impact of the Gut Microbiome on Obesity

Investigating the Stability of Lycopene Formulations

Key Considerations When Outfitting a Preclinical In Vivo Imaging Laboratory

Labelling Pancreatic Islets for Transplantation Using NMR

Low-Dose PET/CT Reduces Radiation Dose Exposure in Preclinical Research

Magnetic Resonance Imaging for Evaluating Heart Health

Magnetic Resonance Imaging of Noradrenergic Neurons

Mapping Biological Samples with microCT

Marine Invertebrates as a Solution to Antibiotic Resistance

Measuring Radiotherapy Dose Distributions using EPR Spectroscopy

Metabolomics in the Study of Soil Toxicity

Micro Computed Tomography for Muscle Mass Evaluation

Micro-CT in Preclinical Imaging: Bone Regeneration in Three Dimensions

Micro-CT of Dental Samples for Forensic Analysis

minispec TD-NMR Analyzer for Determining Oil and Moisture in Seeds and Nuts

Monitoring Photodegradation with EPR Spectroscopy

mq-ProFiler: Portable TD-NMR Analyzer for Quality Control and Research

NMR Analysis to Characterize Beer Profiling

NMR and MRI Technology Identifies Factors in Seed Germination

NMR can Provide Accurate and Reliable Time of Death Analysis in Forensic Science

NMR in Biology: An Overview

NMR Spectroscopy in Food Safety Maintenance

NMR Spectroscopy in the Battle Against Food Fraud

NMR Spectroscopy in the Search for Natural Food Preservatives

NMR Techniques for Intrinsically Disordered Proteins (IDPs)

NMR: A Technique for Detecting Alcohol Fraud

NMR-based Metabolomics Determines Beneficial Fermentation Characteristics of Lactic Acid Bacteria

Novel MRI methodology facilitates evaluation of sporadic cancer in mouse models

Novel NMR Bioreactor Identifies Naturally-derived Drug Candidates

Novel Use of EPR Spectroscopy to Study In Vivo Protein Structure

Nuclear Magnetic Resonance Helps Researchers Improve Drug Delivery

Nuclear Magnetic Resonance Reveals New Drug Compounds

Optimizing the Maillard Reaction to Improve Food Flavor and Taste

Preclinical Brain Imaging: The Use of dMRI

Preventing Food Fraud in Fish

Preventing Ventilator-Associated Pneumonia with NMR

Quantification of Lipoprotein Profiles Using NMR Spectroscopy

Recent Advances in NMR Software for Organic Chemistry Synthesis Control

Revealing the Chemical Composition of e-Cigarettes

Role of Apolipoprotein C3 in Lipid Metabolism

Silencing of Chalcone Synthase in Maize Plant Mutant Increases Lignin Content

Small Animal Imaging Brings Insight to Neurodegenerative Disease

Solid Fat Content Determination by Time Domain (TD) NMR Analysis

SPIONdex Particles: A Candidate Non-Immunogenic MRI Contrast Agent

Structural Analysis of Plant Pigments

Studying the Dynamics of Entangled Fluid Polymers

Studying the Evolution of Protein-Protein Interactions with NMR

Tackling New Psychoactive Substances with NMR Technology

The Bedbug Aggregation Pheromone and NMR Spectroscopy: An Overview

The PROFILE NMR Technique to Characterize Monoclonal Antibodies

The Role of 1H NMR and Chemometrics Analysis in Scotch Whiskey Analysis

The Role of NMR in Fat Crystallization

Understanding the Antioxidant Properties of Coffee

Untangling the Lipid Paradox in Rheumatoid Arthritis

Use of EPR in Monitoring the Effects of Air Pollution

Using Bruker's minispec System for R&D and QC in the Chocolate Field

Using Imaging Techniques to Assess the Effects of a Stroke

Using Magnetic Compounds to Reduce Toxicity of Heavy Metal Cancer Treatments

Using microCT to Identify Micro Snail Species

Using microCT to Research Targeted Approaches to Triple-Negative Breast Cancer

Using minispec Contrast Agent Analyzer for Studying the Effect of MRI Contrast Agents

Using MRI and Positron Emission Tomography to Monitor Mice Brains During Depression

Using NMR and MD Simulation to Study Helicity in IDPs

Using NMR in Characterizing Cocaine

Using NMR to Characterize Orchid Polysaccharides for Potential Pharmaceuticals

Using NMR to Differentiate Adulterated Honey from Natural Honey

Using NMR to Evaluate the Impact of Diet on Cardiovascular Health

Using Nuclear Magnetic Resonance for Complete Analysis of New Psychoactive Substances

Using Nuclear Magnetic Resonance Spectroscopy for In Situ Analysis of Natural Samples

Using Online NMR Reaction Monitoring to Understand Mechanisms and Kinetics of Chemical Reactions

Using Preclinical MRI to Image White Matter Injury

Using Proton NMR to Identify Fraudulent Cocoa Samples

Using Resting-State Functional MRI for Fine-Grained Mapping of Mouse Brain Functional Connectivity

Using Structural Analysis to Improve Anti-TNF Treatments

Using TD-NMR Analysis for Fast and Reliable Quality Control for Toothpaste Production

Validating Hits Through NMR as an Orthogonal Biophysical Method

Webinar Overview: Detecting and Identifying Environmentally Persistent Free Radicals with EPR

Webinar Overview: Using Stop-Flow Techniques NMR and IR, to Optimize Reaction Conditions

News-Medical.Net provides this medical information service in accordance with these terms and conditions. Please note that medical information found on this website is designed to support, not to replace the relationship between patient and physician/doctor and the medical advice they may provide.

News-Medical.net - An AZoNetwork Site

The role of micro-CT in orthodontic bracket removal procedures

Chain Saw Files Owned and operated by AZoNetwork, © 2000-2024